In the event that your Eagle 1000 Series Stratch Wrapper fails to operate and the film carriage stop safety switch on the bottom is not resting on something, use these instructions to reset your machine.

1) Use fork lift to pick machine up about 5” off the ground.
2) Go ahead and turn the power on the machine.
3) Move black dial over to “HAND” mode.
4) Press the blue button for manually raising the carriage.
5) Allow the carriage to travel up about 15” to 20” and then press the blue button again to stop it from traveling.
6) Set the machine back on the ground.
7) Turn black dial over to “Auto” mode.
8) Go ahead and press the reset back to home.
 